TECHNINIŲ DUOMENŲ LAPAS
15.02.2010

Merit Zircon Extra 25 - Acid-catalysed lacquer

 
Merit_Zircon_Extra_25
APIBŪDINIMAS A one component acid catalysed lacquer.
SAVYBĖS

 A fast curing all-round lacquer without armotic solvents.  Easy to sand. Low formaldehyde content.

Paskirtis Suitable for priming and top lacquering of furniture, doors and other wooden surfaces in general.

TECHNINIAI DUOMENYS
Blizgumo standartas ISO 2813/60º
Teorinė išeiga

8,0 m2/l (30 μm DFT).


Practical coverage depends on the application method, laquering conditions and the shape and roughness of the surface to be coated.
Skiediklis 1035, 1033 ir 1058
Įrankiai

Stir the lacquer carefully. Depending on the application technique thin the lacquer with Thinner 1058, 1059, 1033 or 1035. Do not use iron containers as mixing container. Instead use plastic, enamel or acid resistant steel containers.

Džiūvimo laikas

80 - 100 g/m2

 

Dry to sand after 30 minutes in the oven temperature 50 ºC

Dry to sand after 60 minutes in room temperature (23 ºC)

 

Dry to stack after 50 minutes in the oven temperature 50 ºC

Dry to stack after 2 ½ hours in room temperature (23 ºC)

 

Flash Off 3-5 minutes needed before conventional drying. Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation. Stacking temperature of the painted object below 35 ºC. IR-drying is not recommended.

Sausasis likutis 26 % by volume, 34 % by weight.
Tankis 0.95 kg/litre
Sandėliavimas 12 months.
Gaminio kodas 005 2717

NAUDOJIMO INSTRUKCIJA
Dengimo sąlygos The surface to be treated has to be clean and dry. During application and drying the temperature of the air, the surface to be treated and the lacguer has to be over 18ºC and the relative humidity of the air below 70%.

Airless spraying application with the viscosity 30 - 50 seconds (DIN 4) can be reached with approximately 5 - 20 % of thinning by volume. Nozzle tip 0.011" to 0.015" is recommended to use with the pressure of 120 - 160 bar. Spray angle shall be chosen according to the shape of the object.

Air assisted airless application with the viscosity 30 - 50 seconds (DIN 4) can be reached with approximately 5 - 20 % of thinning by volume. Nozzle tip 0.011" - 0.015" is recommended to use with the pressure 40 - 120 bar. Atomising air pressure should be about 1 - 3 bar. Spray angle shall be chosen according to the shape of the object.

Conventional application with the viscosity 30 - 60 s (DIN 4) can be reached with approximately 0 - 20 % thinning by volume. Nozzle tip 1.4 - 1.8 mm is recommended to use with the pressure 2,0 - 3,0 bar.

Curtain coating with the viscosity 35 -56 s (DIN 4) can be reached with approximately 5 - 15 % thinning by volume. Avoid too high pumping pressure and flowing speed.

Komponentų maišymas Product is one-component, no acid catalyser needed. Stir the lacquer carefully before use. Thin the lacquer to the viscosity required. Do not use iron containers as mixing container. Instead use plastic, enamel or acid resistant steel containers.
Įrankių valymas Thinner 1058, 1059, 1033 or 1035.
Lakiųjų organinių junginių kiekis (LOJ) (direktyva 2004/42/EB) The Volatile Organic Compounds amount (thinned 20 % by volume) to 640 g/litre of paint. For industrial use only.

SAUGOS IR SVEIKATOS APSAUGOS ŽENKLINIMAS
pagal reglamentą EB Nr. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oy.